How to Read a Peptide Certificate of Analysis (CoA)
Kineris Labs · Updated 27 October 2026 · 2 min read · 3 references
A Certificate of Analysis is the only document that links the vial in front of you to a measurement of what is inside it. This guide goes through a peptide CoA field by field, explains what each result means, and lists the gaps to look for.
This article summarises published scientific literature for research context. It is not medical advice and makes no claim about the effects of any Kineris product. Findings described here come from the cited studies, most of them in animal or cell models. All Kineris products are supplied for laboratory research use only and are not for human or veterinary use.
The fields, one by one
| Field | What it should show | What to check |
|---|---|---|
| Product name | The compound, including salt form where relevant (for example "BPC-157 acetate") | Matches the product you ordered |
| Batch or lot number | A unique identifier for one production batch | Identical to the number on your vial |
| Laboratory | The name of the lab that ran the test | An independent lab you can contact or verify online |
| Test date | When the sample was analysed | Recent enough to match current stock |
| Method | For example "RP-HPLC, UV 214 nm" and "ESI-MS" | A named method, not just "HPLC" |
| Purity | A percentage from HPLC, ideally with the chromatogram | The chromatogram shows one dominant peak |
| Identity | Measured mass against theoretical mass | The two agree closely |
| Quantity or content | Measured amount of peptide in the vial, where tested | Consistent with the labelled amount |
Purity by HPLC
Reversed-phase high-performance liquid chromatography (RP-HPLC) separates the components of a sample by how strongly they bind to a hydrophobic column. A UV detector records each component as a peak, and purity is the area of the main peak as a percentage of the total peak area.[1] A good CoA includes the chromatogram itself. A single dominant peak with small, well-separated minor peaks is what a high-purity result looks like. See HPLC purity explained for what the number does and does not cover.
Identity by mass spectrometry
HPLC alone cannot tell you that the main peak is the right molecule. Mass spectrometry measures the mass of the molecules in the sample, and a CoA should show the measured mass beside the theoretical mass of the expected sequence.[2] A mismatch means the vial contains something other than what the label says, whatever its purity. Our guide to mass spectrometry and peptide identity covers how to read this result.
What a CoA does not tell you
- Net peptide content: HPLC purity ignores counter-ions and water, which can make up a significant share of the powder's weight.[3] See net peptide content versus gross weight.
- Contaminants outside the tests run: endotoxin, heavy metals and residual solvents need their own tests.
- Stereochemistry: some synthesis impurities, such as racemised residues, have the same mass as the target peptide and may not separate by standard HPLC.[1]
- Anything about a different batch: a CoA describes only the batch that was sampled.
Kineris Certificates of Analysis
Every Kineris batch is tested by an independent third-party laboratory, and its CoA is published against its batch number. You can look up any batch on our Lab Testing & CoAs page.
References
- 1.D'Hondt M, Bracke N, Taevernier L, Gevaert B, Verbeke F, Wynendaele E, De Spiegeleer B. Related impurities in peptide medicines. J Pharm Biomed Anal. 2014;101:2-30. doi.org/10.1016/j.jpba.2014.06.012
- 2.Aebersold R, Mann M. Mass spectrometry-based proteomics. Nature. 2003;422(6928):198-207. doi.org/10.1038/nature01511
- 3.Bachem. What does net peptide content mean? Bachem Knowledge Center. www.bachem.com/helpie_faq/what-does-net-peptide-content-mean/